Redundant P4ATX-300W - Rack Mount
Switching Power Supply
|
|
DIMENSION:
(DxWxH) 6.6"x5.9"x3.3" / 170x150x86(mm) |
DC INPUT:
DC Input:
1. AC Input: 95VAC to 264 VAC (Auto Switch)
2. Frequency: 50HZ~60HZ
3. Inrush Current:
20A maximum at 110VAC user cold start
40A maximum at 220VAC user cold startt |
4. Temperature
Coefficient: All output 0.04% per°C max.
5. Short circuit protection:
All output equipped with short circuit protection
6. Over power protection:
Peak power protected to between 130% to 160% of continuous rated
power |
DC OUTPUT:
1. DC Output:
|
Voltage
|
Min. Current
|
Max. Current
|
Wire color
|
| +3.3V |
0.3A |
14A |
Purple |
|
+5V
|
8V
|
30A
|
Red
|
|
+12V
|
4A
|
12A
|
Yellow
|
|
-5V
|
0.1A
|
0.5A
|
White
|
|
-12V
|
0.1A
|
0.8A
|
Blue
|
| +5V SB |
0A |
0.75A |
Brown |
+5V & +3.3V output
maximum 125W.
+5V SB DC output 750mA
When PS-ON is pulled to TTL low, the DC output is to be enabled
When PS-ON is pulled to TTL low, the DC output is to be enabled |
|
2. Output Regulation:
| +3.3V |
+/- 5%
Max. |
|
+ 5V
|
+/- 5% Max.
|
|
+ 12V
|
+/-8% Max.
|
|
-5V
|
+/- 5% Max.
|
| -12V |
+/-
10% Max. |
|
+5V SB
|
+/- 5% Max.
|
|
3. Short Circuit
Protection:
All output equipped with short circuit protection
4. Over Power Protection:
Peak power protected to between 130% SMto 160% Mof continuous rated
power
5. Hot-Swappable And Power Sharing: |
GENERAL SPECIFICATION:
1. Efficiency: 65% at full load 300W continuous maximum output
2. Operation Temperature: 0°CTo 55°C
3. Storage temperature: -20°C To 70°C
4. Humidity: 5 to 90 non-condensing
5. Hold Up Time: 16mS at maximum load and normal input voltage
6. MTPF: 100K hours at 25°C
7. EMI Requirement:
EN 50081-1(1992): EN 55022: 1994/A1: 1995 Class B
EN 61000-3-2/1995
EN 61000-3-3/1995
EN 50024-1(1998): EN 61022-4-2/1995 EN 61022-4-3/1995
EN 61022-4-4/1994 EN 61022-4-5/1995
EN 61022-4-6/1996 EN 61022-4-8/1993
EN 61022-4-11/1994 |
 |
INSTRUCTIONS:
The set still works properly even if the either unit is removed.
The removed unit cannot be use in other machinery nor for the other
purpose. When one unit breaks down, it's LED will blink buzzer will
sound. Push the Reset button and the buzzer will stop. |
|
Copyright© A+GPB Enterprises Inc.
2001-2004, All rights reserved.
|